• Welcome to CableDataSheet, Cable and Wire Technical Consulting Service.
 

News:

You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login
You are not allowed to view links. Register or Login



Main Menu

MIL-W-22758 / MIL-W-8104 / VG 95218-2 Method 4

Started by Ganimedes Reveley, December 29, 2014, 01:22:45 PM

Previous topic - Next topic

Ganimedes Reveley



MIL-W-22758 / MIL-W-8104 / VG 95218-2 Method 4

Test set-up
The single cable to be tested is fixed at an angle of 30° to the verti-cal, weighed down over a reel. The Bunsen burner flame is directed at the cable from below an angle of 60° to the vertical. Tissue paper (S) is stretched out underneath the sample.

Flame temperature
At least 950 °C

Test duration
30 seconds

Compliance criterion
The sample may continue to burn for a maximum of 30 seconds After the flame is removed and the total permissible length of fire damage to the cable is 76 mm. Material dripping off must not ignite the tissue paper (S) stretched out underneath.

You are not allowed to view links. Register or Login

You are not allowed to view links. Register or Login

You are not allowed to view links. Register or Login

Ganimedes Reveley

#1