What is the old and new colour code for cables ?
Wiring for AC and DC power distribution branch circuits are color coded for identification of individual wires. In some jurisdictions all wire colors are specified in legal documents. In other jurisdictions, only a few conductor colors are so codified. In that case, local custom dictates the "optional" wire colors.
IEC, AC: Most of Europe abides by IEC (International Electrotechnical Commission) wiring color codes for AC branch circuits. These are listed in Table below. The older color codes in the table reflect the previous style which did not account for proper phase rotation. The protective ground wire (listed as green-yellow) is green with yellow stripe.
IEC (most of Europe) AC power circuit wiring color codes.
Function label Color, IEC Color, old IEC
Protective earth PE green-yellow green-yellow
Neutral N blue blue
Line, single phase L brown brown or black
Line, 3-phase L1 brown brown or black
Line, 3-phase L2 black brown or black
Line, 3-phase L3 grey brown or black
UK, AC: The United Kingdom now follows the IEC AC wiring color codes. Table below lists these along with the obsolete domestic color codes. For adding new colored wiring to existing old colored wiring see Cook. [PCk]
UK AC power circuit wiring color codes.
Function label Color, IEC Old UK color
Protective earth PE green-yellow green-yellow
Neutral N blue black
Line, single phase L brown red
Line, 3-phase L1 brown red
Line, 3-phase L2 black yellow
Line, 3-phase L3 grey blue
US, AC:The US National Electrical Code only mandates white (or grey) for the neutral power conductor and bare copper, green, or green with yellow stripe for the protective ground. In principle any other colors except these may be used for the power conductors. The colors adopted as local practice are shown in Table below. Black, red, and blue are used for 208 VAC three-phase; brown, orange and yellow are used for 480 VAC. Conductors larger than #6 AWG are only available in black and are color taped at the ends.
US AC power circuit wiring color codes.
Function label Color, common Color, alternative
Protective ground PG bare, green, or green-yellow green
Neutral N white grey
Line, single phase L black or red (2nd hot) -
Line, 3-phase L1 black brown
Line, 3-phase L2 red orange
Line, 3-phase L3 blue yellow
http://www.allaboutcircuits.com/vol_5/chpt_2/2.html
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p1.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p2.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p3.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p4.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p5.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p6.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p7.img&v=00000000-0000-0000-0000-000000000702&usid=fc35219f-eedf-493c-a67e-a818f86b467c&Fi=SDA212A7DB96D6B5B0!1754&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p1.img&v=00000000-0000-0000-0000-000000000702&usid=580783ff-9ad1-48fb-9ceb-42b2e4af35e2&Fi=SDA212A7DB96D6B5B0!1752&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p2.img&v=00000000-0000-0000-0000-000000000702&usid=580783ff-9ad1-48fb-9ceb-42b2e4af35e2&Fi=SDA212A7DB96D6B5B0!1752&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p3.img&v=00000000-0000-0000-0000-000000000702&usid=580783ff-9ad1-48fb-9ceb-42b2e4af35e2&Fi=SDA212A7DB96D6B5B0!1752&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p4.img&v=00000000-0000-0000-0000-000000000702&usid=580783ff-9ad1-48fb-9ceb-42b2e4af35e2&Fi=SDA212A7DB96D6B5B0!1752&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
(https://word-view.officeapps.live.com/wv/ResReader.ashx?n=p1.img&v=00000000-0000-0000-0000-000000000702&usid=a00bff94-335a-4a9d-8fc1-4f0acb5a9057&Fi=SDA212A7DB96D6B5B0!1753&C=5_810_DM2-SKY-WAC-WSHI&ak=m%3Den%2Dus&z=256&waccluster=AM3&PdfMode=1)
https://onedrive.live.com/view.aspx?cid=A212A7DB96D6B5B0&resid=A212A7DB96D6B5B0!1753&app=WordPdf