Def-St. 02-713 (formerly NES 713)/VG 95218-2 Method 1

Started by Ganimedes Reveley, December 29, 2014, 01:36:12 PM

Previous topic - Next topic

Ganimedes Reveley



Def-St. 02-713 (formerly NES 713)/VG 95218-2 Method 1

Test set-up
The individual non-metallic components of the cables are burnt in a test chamber. The toxicity of the fire gas is determined analytically covering 1 substances.

Flame temperature
1150 °C ± 50 °C

Test duration
5 minutes

Compliance criterion
The toxicity readings of the individual non-metallic components of the cable are added according to their proportion of the total volume. The toxicity index for the overall cable must not exceed 5.